This website uses cookies to ensure you get the best experience on our website. Read more
BREAKER 30A S/P H/SIZE
Brand
GENERAL ELECTRIC
In stock
Only 30 left
SKU
GE-THQP130
TTD $79.00
PRODUCT FEATURES
Amps: 30
Volts AC: 120, 240
Poles: 1
Type: Breaker, Miniature, Thin
Interrupt Rating AC: 10000
Amps: 30
Volts AC: 120, 240
Poles: 1
Type: Breaker, Miniature, Thin
Interrupt Rating AC: 10000
INCLUDES
(1) GE Industrial THQP130 Breaker, 30A, 1P, 120/240V, 10 kAIC, Q-Line Series, Thin
PRODUCT DESCRIPTION
Circuit breakers plug-in - single pole - type thqp factory installed lugs"q line" 1/2 inches per pole amp rating=30 Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 inches per p ole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3- 9/32 inches height x 1/2 inches width x 2- 3/8 inches depth. 120/240 volt; 10,000 AIR.
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per p ole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
TECHNICAL SPECIFICATIONS
Part Number: 783164085709
Part: GE Industrial THQP130 Breaker, 30A, 1P, 120/240V, 10 kAIC, Q-Line Series, Thin
30 Amp, 1-Pole, Type Q-Line Circuit Breaker, 10 kAIC, 120/240 VAC. Plug-On Circuit Breaker, Thin Style.
Amps: 30
Volts AC: 120, 240
Poles: 1
Type: Breaker, Miniature, Thin
Interrupt Rating AC: 10000
Package Dimensions ? : ? 8.7 x 6.7 x 0.88 inches; 3.99 Ounces
Item Weight: 0.24lbs
Shipping Weight: 1lb
(1) GE Industrial THQP130 Breaker, 30A, 1P, 120/240V, 10 kAIC, Q-Line Series, Thin
PRODUCT DESCRIPTION
Circuit breakers plug-in - single pole - type thqp factory installed lugs"q line" 1/2 inches per pole amp rating=30 Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 inches per p ole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3- 9/32 inches height x 1/2 inches width x 2- 3/8 inches depth. 120/240 volt; 10,000 AIR.
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per p ole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
TECHNICAL SPECIFICATIONS
Part Number: 783164085709
Part: GE Industrial THQP130 Breaker, 30A, 1P, 120/240V, 10 kAIC, Q-Line Series, Thin
30 Amp, 1-Pole, Type Q-Line Circuit Breaker, 10 kAIC, 120/240 VAC. Plug-On Circuit Breaker, Thin Style.
Amps: 30
Volts AC: 120, 240
Poles: 1
Type: Breaker, Miniature, Thin
Interrupt Rating AC: 10000
Package Dimensions ? : ? 8.7 x 6.7 x 0.88 inches; 3.99 Ounces
Item Weight: 0.24lbs
Shipping Weight: 1lb
| SKU | GE-THQP130 |
|---|---|
| Weight | 1.000000 |
| Manufacturer | GENERAL ELECTRIC |
Write Your Own Review
The attribute color not support show on frontend please choose another attribute.